16 Channel CWDM MUX/DEMUX
Overview
The 16 channel CWDM filters provides a solid capacity solution for modern fiber networks. These filters combine 16 ITU standard CWDM wavelengths from 1271nm to 1610nm onto a single fiber. The modules are available in a single wide single fiber version, with a OTDR port, as well as a two wide LGX modules for dual fiber applications.
CWDM capacity solutions are passive and require no power, or configuration. CWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
Features
- 16 Channel CWDM
- Single or Dual Fiber
- OTDR Port
- Customizable Channels
- Form Factor: LGX
- Temp Range: I-Temp
Environment
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Configurations
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
| PARAMETER | UNIT | SPECIFICATION | ||
|---|---|---|---|---|
| NUMBER OF CHANNELS | CH | 16CH CWDM + OTDR | ||
| OPERATING WAVELENGTH- CWDM | nm | 1270-1610 | ||
| OPERATING WAVELENGTH- OTDR | 1600-1670 | |||
| CWDM CHANNEL SPACING | nm | 20 | ||
| CWDM CHANNEL PASSBAND | nm | 6.5 | ||
| INSERTION LOSS INCL. CONNECTORS | -- | PLO-LACT-EBB1-LC | PLO-BBCT-EBB1-LC PLO-BBCT-EBB2-LC |
|
| COM -- CWDM | MAX. | dB | 3.7 | 3.5 |
| COM – OTDR | MAX. | dB | -- | 1.2 |
| COM -- MON | MAX. | dB | -- | 19 |
| DIMENSIONS (H X W X D): LGX BOX | mm | 58 x 100 x 76 | 29 x 100 x 76 | |
| ADJACENT CHANNEL ISOLATION | MAX. | dB | 30 | |
| NON-ADJACENT CHANNEL ISOLATION | MAX. | dB | 40 | |
| PASS BAND RIPPLE / DWDM | MAX. | dB | 0.5 | |
| PDL /DWDM | MAX. | dB | 0.2 | |
| PMD | MAX. | ps | 0.2 | |
| DIRECTIVITY | MIN. | dB | 50 | |
| RETURN LOSS | MIN. | dB | 45 | |
| POWER HANDLING | MAX. | mW | 300 | |
| OPERATING TEMPERATURE | °C | -40 ~ +85 | ||
| STORAGE TEMPERATURE | °C | -40 ~ +85 | ||
| FIBER TYPE | / | G657A2 | ||
| CONNECTOR TYPE | / | LC/UPC | ||
| PART NUMBER | DESCRIPTION |
|---|---|
| PLO-LACT-EBB1-LC | 2-WIDE LGX, 16 CHANNEL CWDM MUX-DEMUX, ITU 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, LC-UPC |
| PLO-BBCT-EBB1-LC | 1-WIDE LGX, 16 CHANNEL CWDM, SINGLE FIBER, SIDE A, +OTDR, CWDM CH 1271-1571, 2% MONITOR, LC-UPC |
| PLO-BBCT-EBB2-LC | 1-WIDE LGX, 16 CHANNEL CWDM, SINGLE FIBER, SIDE B, +OTDR, CWDM CH 1271-1571, 2% MONITOR, LC-UPC |
| NOTE: SEE PLUGIN OPTICS LGX MOUNTING CHASSIS BELOW. | |
8-Channel CWDM +1310nm MUX/DMX, LGX
Overview
The 8-channel CWDM + 1310nm filter wideband provides a solid capacity solution for modern fiber networks. This LGX module combines 8 ITU standard CWDM wavelengths and a wideband 1310nm wavelength to allow the overlay of legacy 1310nm circuits or the next evolution of 100G circuits.
CWDM capacity solutions are passive and require no power, or configuration. CWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
Features
- 8 Channel CWDM +1310nm
- 9 to 1 Capacity Gain
- Configuration: Mux/Dmx
- 2% Monitor Port
- Form Factor: LGX
- Temp Range: I-Temp
Environment
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Configuration
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
| Parameter | Unit | Specification |
|---|---|---|
| NUMBER OF CHANNELS | CH | 8 CWDM, 1310nm |
| OPERATING WAVELENGTH | nm | 1260 ~ 1620 |
| CWDM CHANNEL SPACING | GHz | 20 |
| PASSBAND: 1310NM PORT | Nm | 1260-1360 |
| PASSBAND: CWDM PORTS | nm | ITU ± 6.5 |
| INSERTION LOSS | dB | 1310nm < 1.5, COM-CWDM <3.3 |
| Part Number | Description |
|---|---|
| PLO-L1CT-A9C1-LC | 8ch CWDM (1471, 1491, 1511, 1531, 1551, 1571, 1591, 1611nm) Plus 1310nm Mux/Demux Filter, Monitor Port, LGX, LC/UPC |
5-Channel CWDM +1310nm & 1550nm MUX/DMX, LGX
Overview
The LGX 5-channel CWDM + 1310nm & 1550nm wideband provides a solid capacity solution for modern fiber networks. This LGX module combines 5 ITU standard CWDM wavelengths with 1310nm and 1550nm wavelengths to allow the overlay of legacy 1310nm and 1550nm circuits or the next evolution of 100G circuits.
CWDM capacity solutions are passive and require no power, or configuration. CWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
Features
- 5 Channel CWDM +1310nm & 1550nm 7 to 1 Capacity Gain
- Configuration: Mux/Dmx
- 2% Monitor Port
- Form Factor: LGX
- Temp Range: I-Temp
Environment
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Configuration
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
| Parameter | Unit | Specification |
|---|---|---|
| NUMBER OF CHANNELS | CH | 5 CWDM, 1310nm, 1550nm |
| OPERATING WAVELENGTH | nm | 1260 ~ 1620 |
| CHANNEL SPACING | nm | 20 |
| PASSBAND: 1310 CHANNEL | nm | 1260- 1360 |
| PASSBAND: 1550NM CHANNEL | nm | 1527- 1566 |
| PASSBAND: 1471-1611 CHANNELS | nm | ITU ± 6.5 |
| INSERTION LOSS | dB | 1310nm < 1.5, 1550nm< 1.8, COM-CWDM <2.7 |
| Part Number | Description |
|---|---|
| PLO-L1CT-C7C1-LC | LGX, 7 CHANNEL, CWDM MUX-DEMUX, 1471-1491-1511, 1591-1611, 1310NM, 1550NM, 2% MONITOR, LC-UPC |
1-Channel CWDM OADM, LGX
Overview
CWDM Optical Add/Drop Multiplexers (OADM) allow for midspan access of CWDM channels along a single mode fiber route. 1-channel CWDM OADMs are commonly used at sites along a fiber route carrying 8 CWDM channels and allow access to 1 channel while expressing the remaining channels through the site.
PlugIn Optics CWDM OADM filter solutions are passive and require no power, or configuration. OADM filters are used to allow adding and dropping of CWDM wavelengths, West and East, along a single mode fiber route and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
.
Features
- Add/Drop: 1 DWDM Channel
- Monitor Port: 2%
- 40 Variants: ITU Ch 20-59
- Technology: DWDM
- Configuration: OADM
- Form Factor: LGX
- Temp Range: I-Temp
Environment
- 1 Channel Add/Drop
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
Configuration
- Central Office, Head End, Data Center
- Pedestal, Cabinet, MDU
| Parameter | Unit | Specification |
|---|---|---|
| NUMBER OF CHANNELS | CH | 1 CWDM, WEST & EAST |
| OPERATING WAVELENGTH | nm | 1471- 1611 |
| CWDM CHANNEL SPACING | nm | 20 |
| PASSBAND: EXPRESS | nm | 1435-1625 |
| PASSBAND: CWDM CHANNELS | nm | ITU ± 6.5 |
| INSERTION LOSS | dB | EXP< 2.0, COM-CWDM <1.3 |
| Part Number | Description |
|---|---|
| PLO-L3CT-B101-LC | LGX, 1 CHANNEL CWDM OADM, 1471NM, 2% MONITOR, LC-UPC |
| PLO-L3CT-B102-LC | LGX, 1 CHANNEL CWDM OADM, 1491NM, 2% MONITOR, LC-UPC |
| PLO-L3CT-B103-LC | LGX, 1 CHANNEL CWDM OADM, 1511NM, 2% MONITOR, LC-UPC |
| PLO-L3CT-B104-LC | LGX, 1 CHANNEL CWDM OADM, 1531NM, 2% MONITOR, LC-UPC |
| PLO-L3CT-B105-LC | LGX, 1 CHANNEL CWDM OADM, 1551NM, 2% MONITOR, LC-UPC |
| PLO-L3CT-B106-LC | LGX, 1 CHANNEL CWDM OADM, 1571NM, 2% MONITOR, LC-UPC |
| PLO-L3CT-B107-LC | LGX, 1 CHANNEL CWDM OADM, 1591NM, 2% MONITOR, LC-UPC |
| PLO-L3CT-B108-LC | LGX, 1 CHANNEL CWDM OADM, 1611NM, 2% MONITOR, LC-UPC |
2 Channel, Single Fiber, CWDM MUX/DEMUX
Overview
These 2CH CWDM +EXP filters are designed to be spliced in along a route to gain access to two channels along the route.
CWDM capacity solutions are passive and require no power, or configuration. CWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.
Features
- 2CH CWDM
- Single Fiber
- Customizable Channels
- Form Factor: Component
- Temp Range: I-Temp
Environment
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Configurations
- Linear Chain
- Collapsed/Diverse Ring
- Splice In
| PARAMETER | UNIT | SPECIFICATION | |
|---|---|---|---|
| NUMBER OF CHANNELS | CH | 2 CWDM + OTDR | |
| OPERATING WAVELENGTH- CWDM | nm | 1270-1610 | |
| CWDM CHANNEL SPACING | nm | 20 | |
| CWDM CHANNEL PASSBAND | nm | 6.5 | |
| INSERTION LOSS INCL. CONNECTORS | -- | PORT VALUE | |
| CWDM | MAX. | dB | 1.0 |
| EXP | MAX. | dB | 1.0 |
| ADJACENT CHANNEL ISOLATION | MAX. | dB | 30 |
| NON-ADJACENT CHANNEL ISOLATION | MAX. | dB | 40 |
| PASS BAND RIPPLE / DWDM | MAX. | dB | 0.5 |
| PDL /DWDM | MAX. | dB | 0.2 |
| PMD | MAX. | ps | 0.2 |
| DIRECTIVITY | MIN. | dB | 50 |
| RETURN LOSS | MIN. | dB | 45 |
| POWER HANDLING | MAX. | mW | 300 |
| OPERATING TEMPERATURE | °C | -40 ~ +85 | |
| STORAGE TEMPERATURE | °C | -40 ~ +85 | |
| FIBER TYPE | / | .9MM LOOSE TUBE, G657A2 | |
| CONNECTOR TYPE | / | NONE | |
| PART NUMBER | DESCRIPTION |
|---|---|
| PLO-BBCT-E2B1-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1271-1291, 1METER, 900 MICRON |
| PLO-BBCT-E2B2-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1311-1331, 1METER, 900 MICRON |
| PLO-BBCT-E2B3-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1351-1371, 1METER, 900 MICRON |
| PLO-BBCT-E2B4-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1391-1411, 1METER, 900 MICRON |
| PLO-BBCT-E2B5-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1431-1451, 1METER, 900 MICRON |
| PLO-BBCT-E2B6-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1471-1491, 1METER, 900 MICRON |
| PLO-BBCT-E2B7-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1511-1531, 1METER, 900 MICRON |
| PLO-BBCT-E2B8-00 | 2 CHANNEL CWDM, SINGLE FIBER, PIGTAIL, 70MM× 45MM × 8MM BOX, MUX, +EXP, CWDM CH 1551-1571, 1METER, 900 MICRON |
| NOTE: THE ABOVE LIST CONTAINS THE MUX VARIANT OF EACH FILTER. FOR MATCHED PAIR FILTERS, USED IN PTP APPLICATIONS, CONTACT US FOR DEMUX VARIANTS. | |